*Kinetex analytical columns are compatible with all LC systems with standard LC column end-fittings threaded in 10-32. Please contact us for any questions and information about fitting compatibility and any other column internal diameters.
Carbon Load 8 (effective), 8 (effective) % |
Recommended Use Minimized hydrophobic retention for highly hydrophobic compounds |
Surface Area (m²/g) 200 |
Particle Size 1.7, 2.6, 5 |
Recommended Use Minimized hydrophobic retention for highly hydrophobic compounds |
The Kinetex core-shell C8 provides the same Kinetex performance but with a little less hydrophobic retention in comparison to the Kinetex C18 column. This C8 column is ideal for extremely hydrophobic compounds that might be too strongly retained on a traditional C18 phase column.
As part of the broader Kinetex HPLC Column family, Kinetex C8 HPLC column combines innovative core-shell particle technology with C8 chemistry to deliver high efficiency, excellent selectivity, and reliable durability. It balances retention strength with speed, making it suitable for a wide range of applications. ,
Retention and Selectivity
The C8 column provides balanced retention, ideal for extremely hydrophobic compounds that might be retained too strongly with the C18 phase column. It ensures improved peak shape, reproducibility, and resolution compared to traditional fully porous columns.
Efficiency
The core-shell design enhances mass transfer, reducing band broadening and delivering sharper peaks and higher sensitivity. It gives you similar performance as a smaller particle column but with a much lower backpressure.
Faster Analysis
Less surface area because of the solid core in the middle allows shorter run times without compromising separation quality, improving lab throughput.
Versatility and Durability
Suitable for pharmaceutical, environmental, and food analysis, the column resists solvent degradation and ensures long-term stability.
Proper care of the Kinetex C8 column extends its life and preserves performance. Follow these best practices from the Kinetex care guide:
If you are planning your next method development, make sure to choose the right HPLC column for your analytes to achieve optimal efficiency and reproducibility.
The C8 column HPLC operates effectively between pH 1.5–8.5, offering flexibility for acidic to neutral mobile phases. pH stability is 1.5-10 under isocratic conditions.
The maximum operating temperature is typically 60 °C, allowing stable performance without risk of degradation.
You can inject check standard and run as column CQA to make sure the column is performing properly.
Remove the buffer first and store in high organic like 80:20 acetonitrile/water with end plugs secured. Avoid pure water for long-term storage to prevent microbial growth.
The C8 column provides shorter retention and faster elution than C18, making it better for moderately to high hydrophobic compounds or when shorter run times are required.
Yes, Kinetex C8 columns are designed for both HPLC and UHPLC, offering high efficiency and compatibility with modern systems.